UNCONTROLLED COPY — SOP-001 Cleaning and sanitising the filling line, revision 2.0. Check the current revision before use.

SOP-001 Cleaning and sanitising the filling line

Revision
2.0
Effective from
2026-11-02
Owner
Ben Carter
Approved
2026-11-02

1. Purpose

Remove product residue and microorganisms from the filling line between batches.

2. Scope

Line 1 filler, capper and the connecting pipes.

3. Procedure

  1. Stop the line and lock out the filler.

  2. Rinse with water at 80 °C for 10 minutes.

  3. Circulate the caustic solution (1.5 %) for 20 minutes.

  4. Rinse until the conductivity is back to the water reading.

  5. Take ATP swabs at the five marked points. Pass: below 150 RLU.

  6. Record the cleaning on form FRM-001.

4. Records

Cleaning records are kept for two years.